2.9.3 Changing Lenses
As described in section 2.9,
Lens Options
, the
M22M can be fitted with several MOBOTIX
lenses. Proceed as follows to change a lens:
• Unmount the lens cover by turning it
counter-clockwise.
• Loosen the lens' lock ring (if fitted) by turn-
ing it counter-clockwise.
• Remove the lens with the lock ring by
turning it counter-clockwise.
• Unscrew the lock ring (if present) from the
lens you just removed and screw it onto the
new lens.
• Screw the new lens with the lock ring (if present) back into the camera.
• If necessary, restore the power supply of the camera.
• Adjust the image sharpness according to the camera's live image on the
computer monitor. Never turn the lens to far into the lens mount and never
apply excessive force when doing so as this would damage the lens mount
otherwise.
• Tighten the lock ring by turning it in clockwise direction.
This procedure is the same for the M22M-Sec-CSVario and CS/C mount lenses,
albeit without the lock ring (not installed).
2.10 Wiring, Fire Prevention, Lightning and Surge Protection
When installing the wiring inside or outside of buildings, make sure you always
adhere to the relevant regulations on wiring, fire prevention and protection against
lightning.
MOBOTIX recommends having MOBOTIX cameras installed only by specialists
accustomed to installing network devices and having proper respect for the pertinent
regulations regarding lightning protection and fire prevention as well as the current
technology for preventing damages from electrical surges.
Find more information at an institution such as the International Electrotechnical
Commission (IEC, www.iec.ch) or at a manufacturer of protection devices against
lightning and electrical surges, such as Dehn (www.dehn.de).
2.10.1 Wiring
When installing the wiring, make sure you follow these guidelines:
• Data cable: Make sure you only use double-shielded
CAT 5/7 cable (S/STP) for Ethernet connections. Double-
shielded means that the cable as a whole is shielded
and that each twisted wire pair has its own shield.
© MOBOTIX AG • Security-Vision-Systems • Made in Germany
41/76
M22M Camera Manual Part 1
Caution: Protection class
IP65 will only be reached
with mounted lens cover
Check image sharpness!
Use double-shielded CAT
5/7 cables for wiring
Komentáře k této Příručce